Ceramic Manufacturing
1,280°C computer-controlled tunnel kiln firing ensuring vitrified, non-porous ceramic bodies.
MICAWA manufactures one-piece, two-piece, wall-hung and smart toilets in Foshan, China, for distributors, bathroom brands and project contractors. Every order is specified by rough-in, outlet type, flush volume and destination certification — the four parameters that decide whether a container clears site inspection, not just the catalogue page.
Browse one-piece, two-piece, wall-hung and smart toilets in one place. Filter by toilet type and open a model to review its specifications.
Explore our targeted manufacturing programs built for commercial distribution, high-density residential developments, and branded retail lines.
Integrated ceramic toilets for residential, hospitality, wholesale and private-label programs. Multiple rough-in, flushing and OEM configurations are available by model.
Close-coupled ceramic toilets with a separate bowl and cistern. A practical, cost-efficient choice for volume distribution, rental apartments and standard residential projects.
Wall-mounted ceramic toilets that keep the floor clear for easier cleaning and save usable space. They require a concealed in-wall carrier frame confirmed against the wall construction.
Integrated electronic toilets across five series (17 configurations, including floor-standing and wall-hung models) — from heated-seat light-smart tiers to zero-pressure, app, voice and foam-shield packages.
These four are not variations of one product. They differ in flush architecture, outlet, structural requirement and installation order — and each difference lands on site as a cost, not just as a line on a spec sheet.
| Decision Point | One-Piece | Two-Piece | Wall-Hung | Smart Toilet |
|---|---|---|---|---|
| Flush architecture | Siphon — vortex or jet by model; trapway and water seal sit inside one ceramic body | Siphon or wash-down; tank and bowl are a matched set and must be ordered as one unit | Wash-down with a horizontal outlet; the valve sits behind the wall or a panel | Powered siphon or jet siphon; flush, wash and dry share one power supply |
| Outlet and rough-in | Floor outlet (300 / 400 mm across 19 models) or rear wall P-trap H180 mm (MB-1898H) | Floor outlet (300 / 400 mm) or optional wall H180 mm (MB-2803); confirm tank-to-wall gap | Wall outlet; horizontal discharge height set by the concealed carrier frame and wall build-up | Floor outlet (300 / 305 / 400 mm), optional wall-drain MB-1960, or wall-hung MB-2889ASJ |
| Structure required | None beyond a level floor | None beyond a level floor | Load-bearing wall or a steel carrier frame cast in — a structural decision, not a product option | A power point within reach of the unit |
| Power | Not required | Not required | Not required | Required; listed models are AC220V / 50Hz — confirm voltage, frequency and plug per market |
| Installation order | Set the flange and seal, place the unit, connect water, test flush | Bowl first, then set and seal the tank, then connect | Frame first, then finish the wall, then hang the bowl — the bowl cannot go up before the wall is closed | Plumbing and power rough-in first, unit second, commissioning last |
| Service access | Inlet and flush valve reached through the lid or a side opening | Lid off; tank internals fully exposed | Needs a flush plate or access panel — fix its position before the wall closes | Board and pump need a service route; confirm it per model |
| Parts that wear out | Inlet valve, flush valve, seat and cover | Same set plus the tank-to-bowl gasket | Carrier frame fixings, flush valve, seat and cover | Seat assembly, control board, inlet valve, remote |
| Failure to design around | Trapway blockage — check the local minimum ball passage against the model | Leak at the tank gasket when the two surfaces do not seat flat | Frame fixed to a non-load-bearing wall — the most common site failure | Power loss and inlet pressure below the model minimum |
| Where it fits | Exposed bathrooms, retail cartons, sites where one body is easier to handle | Volume rental and cost-led projects, tighter stowage per container | Compact and accessible layouts where floor area is the constraint | Premium suites, hotels and high-rise apartments (zero-pressure tank & dual-pump options available) |
Jump directly into any of MICAWA’s 27 traditional one-piece, two-piece, or wall-hung ceramic toilet datasheets grouped by bowl projection, rough-in format, and flushing architecture.
| Format & Sizing Tier | Outlet & Rough-In | Procurement Highlights | Direct Model Datasheets |
|---|---|---|---|
| Compact One-Piece · 660–685 mm Projection | Floor outlet · 300 / 400 mm rough-in | Short projection for apartment pods & small guestrooms; ~310 pcs/40HQ (MB-1906) | |
| Standard Project Siphon · 680–710 mm | Floor outlet · 300 / 400 mm rough-in | 4.5L–4.8L dual-flush workhorses for hotels, serviced apartments & offices | |
| Super-Vortex & Architectural · 680–735 mm | Floor outlet · 300 / 400 mm rough-in | Rimless swirl & broad comfort suites for 4- to 5-star hospitality builds | |
| Rear Wall-Outlet (H180 mm) & Two-Piece Split | Wall P-trap H180 mm · or Two-piece 300/400 mm | Same-floor rear plumbing & boxed split-cistern volume (~380–400 sets/40HQ) | |
| Concealed-Carrier Wall-Hung · 515–570 mm | Horizontal wall outlet · Steel carrier frame | Clear-floor sanitary hygiene & 480–550 pcs/40HQ loading efficiency |
Confirm each factor at category level first — the specific answers live on the relevant one-piece or smart toilet range.
| Check | Why it matters | Where to continue |
|---|---|---|
| Rough-in and outlet | A 300 mm and a 400 mm rough-in are not interchangeable once the floor is finished | Confirm per model |
| Flush volume and dual flush | Destination markets set minimum or maximum flush volumes; the wrong one fails inspection | Confirm per model |
| Trapway ball passage | Several codes specify a minimum ball passage — a smaller trapway can pass factory testing and still fail site inspection | Confirm per model |
| Certification scope | Certificates name specific models; a certificate for one model does not cover the rest of the range | Review certification scope |
| Wall structure | On wall-hung units the carrier frame has to go into a load-bearing wall or a steel frame | Wall-hung models |
| Power supply | Listed smart models run AC220V / 50Hz; voltage, frequency and plug must match the destination | Smart toilet models |
| Seat and cover specification | PP and UF behave differently under public use, and soft-close and quick-release are separate options | Confirm per model |
| Spare parts and after-sales | Seats, valves and control boards have to stay available for the life of the project, not just the first order | Request the parts list |
| Packaging and container plan | Carton size and stowage decide freight cost per set, and whether pallet or floor loading is cheaper | Request a quotation |
We integrate deep sanitary ceramic manufacturing expertise with turnkey B2B export coordination.
1,280°C computer-controlled tunnel kiln firing ensuring vitrified, non-porous ceramic bodies.
Flush behaviour is recorded during production checks and can be reviewed before ordering. Ask for a flush demonstration of the model you are evaluating; third-party ratings are quoted per model only where a report is available.
Support for ceramic mold development, laser branding, custom packaging, and electrical adapting.
600,000 pcs annual sanitary ceramic capacity built to support container-load wholesale programs.
Rigorous multi-stage inspection across surface glaze, dimension tolerance, flush function, and seat endurance.
Export documentation, packing agreed per order, and container stowage planning. Carton grade, internal protection and pallet or crate configuration are confirmed against the model and the delivery route before shipment.
Recorded demonstration
Flush behaviour is difficult to judge from still images. This recording shows one complete cycle on a MICAWA ceramic toilet under factory test conditions — standing water, the flush, drainage, and the bowl refilling to its standing level.
Five stages decide whether a toilet arrives in the condition it left the kiln. What follows is what each stage is meant to catch — the model-level figures sit on the category and model pages, not here.
High-pressure casting and controlled body forming, with dimensional checks on the green body before glazing — a body that is out of tolerance here cannot be corrected later.
Glaze is applied and fired at 1,280°C in the computer-controlled tunnel kiln; the 18-hour cycle is what vitrifies the body and brings water absorption down to the vitreous range.
Flush and drainage checks are run on the models specified for them. Results are model-specific — they are not a blanket figure for the whole range.
Seat, inlet valve, flush valve and electronic modules are checked against the configuration ordered, because a substituted component is the most common reason a batch fails on site rather than in the factory.
Appearance, dimensions, function and carton configuration are checked before loading. Carton grade and internal protection are agreed per model and route, not assumed from a catalogue.
Detailed performance data, water consumption, electrical ratings and test results vary by model. Review the relevant category or product technical sheet before approval.
Model-level data: one-piece ceramic performance & test results → smart toilet electrical & water ratings →
MICAWA supports toilet sourcing programs for distributors, bathroom brands and project buyers, including:
| Buyer Parameter | Standard Terms & Confirmation Points |
|---|---|
| Sample & Trial Order | Start with a sample or small trial order to verify product quality before scaling up. |
| Sample Availability | Physical samples for dimensional inspection and flush testing are available upon configuration review. |
| Production Lead Time | Confirmed after model, quantity, packaging, inspection requirements and delivery destination are finalized. |
| Export Master Packaging | Carton grade, internal protection and pallet or crate configuration are agreed per model, order volume and route, then confirmed in the order documents. Custom retail boxes are available for OEM programmes. |
| Technical Documentation | CAD dimension drawings, plumbing rough-in templates, exploded parts lists, and compliance documents supplied. |
| Quotation Inputs Required | Provide target market, buyer type, preferred toilet category, estimated quantity, required certification, and any OEM requirements. |
Follow the route that matches your distribution, private-label, public engineering, hospitality, or property-development requirements.
Build a repeatable one-piece and smart toilet range around catalog stability, container planning, and localized packaging.
Explore Toilet CollectionsDevelop differentiated private-label product lines with customized ceramic profiles, laser logos, and bespoke retail boxes.
OEM & Private Label ToiletsCoordinate product quantities, installation interfaces, available documentation, and phased delivery requirements for public-sector washroom projects.
Public Engineering SolutionsCoordinate toilet selections with bathroom layouts, project quantities, and related fixtures for hotel and commercial washroom programs.
Hotel & Commercial SolutionsPlan repeatable toilet and bathroom product packages around unit types, project phases, and site-delivery requirements.
Property Development SolutionsOur production complex utilizes automated high-pressure casting systems and twin 123-meter tunnel kilns to guarantee output stability and strict batch consistency.
Explore MICAWA factory capability
Use these technical and procurement guides to compare toilet formats, flushing systems, bowl heights, sample inspection criteria and hospitality requirements.
Compare ceramic construction, container loading density, installation labor, maintenance and B2B unit economics.
Read Buyer GuideMatch trapway design, water surface area, rough-in conventions and regional plumbing codes to your destination market.
Read Buyer GuideCompare standard 15-inch and comfort/ADA 17–19 inch bowl heights for residential, hospitality and accessible washroom projects.
Read Buyer GuideVerify glaze uniformity, water absorption, trapway glazing, flush performance and dimensional tolerances during sample approval.
Read Buyer GuideAlign voltage, water pressure minimums, hygiene controls, spare parts and guestroom maintenance before hospitality procurement.
Read Buyer GuidePrepare rough-in dimensions, flushing standards, glaze checks and container mix inputs before requesting a sanitary ware quote.
Read Buyer GuideSeparate metric 300/400 mm floor S-traps, US 10/12/14-inch flanges, and rear H180 mm wall P-traps before ordering molds.
Read Buyer GuideVerify 180/230 mm carrier bolt spacing, FFL rim elevation math, supply scope split, and 480–550 pcs/40HQ container yields.
Read Buyer GuideDirect answers to core procurement, technical spec, and OEM questions.
One-piece is a single ceramic body: one joint fewer to seal, one unit to handle, and a cleaner line where the toilet is exposed. Two-piece ships as bowl plus tank, costs less per set and stows tighter per container, but it has a tank-to-bowl gasket that has to seat flat or it will leak. Volume rental and cost-led projects usually go two-piece; exposed bathrooms and retail cartons usually go one-piece.
A carrier frame fixed to a load-bearing wall or a steel frame built into the wall, the outlet height set from the finished floor, and a flush plate or access panel for service. The bowl cannot be hung until the frame is set and the wall is closed, so the frame is a line item in the project budget, not an accessory.
The listed models run AC220V / 50Hz and need a power point within reach. Inlet pressure depends on configuration: built-in tank and dual-pump models (MB-1865AS/AJS, MB-1960FS/FSJ/AS/ASJ, MB-1871FS/AS and MB-1876B/BJS) support zero-water-pressure operation, while direct-feed models require adequate mains pressure. Voltage, frequency, plug type and pressure are confirmed against the destination market before the model is approved.
Certificates name individual models and their scope. A certificate issued for one model does not cover the rest of the range, and the available CCC evidence covers listed smart-toilet models only. Tell us the destination market and the standard being applied, and we confirm which models carry which certificate before approval.
MOQ depends on the project rather than a fixed figure, and mixed models can ship in one container. The minimum is confirmed against the model mix, the quantity split and the destination — send those three, plus any OEM or packaging requirement, and the quotation states the actual minimum.
Consolidate toilets with complementary sanitary ware and cabinetry into unified container shipments to lower freight costs. Review the one-stop bathroom solution for the full mixed-container plan.
Pedestal, countertop, undermount, and wall-hung washbasins for unified bathroom packages.
Explore ceramic basins →Wall-hung and auto-sensor urinals designed for commercial and public washroom developments.
Explore urinal supply →Review our full production portfolio including bidets, sinks, and hardware components.
Explore sanitary ware →Share your target market, preferred toilet category, estimated quantity, certification and OEM requirements. Our export team responds with the relevant category spec sheets and quotations within 24 business hours.
Need customized support? You can also contact us via the main contact page.
We use only necessary browser storage to remember privacy preferences and support core site functions.